BMA Series Generating Set |
Item No | Genset Model | Genset Model | Power Out Put | Beinei | Mecc Alte | |||
Prime 40 ℃ | Standby 27℃ | |||||||
1 | BMA35OP | BMA35SP | 24.8kW | 31.0kVA | 27.8kW | 34.7kVA | F4L912 | ECO32-1S/4 |
2 | BMA39OP | BMA39SP | 28.0kW | 35.0kVA | 31.0kW | 38.8kVA | F4L912T | ECO32-2S/4 |
3 | BMA45OP | BMA45SP | 32.0kW | 40.0kVA | 35.7kW | 44.6kVA | F4L912T | ECO32-3S/4 |
4 | BMA56OP | BMA56SP | 40.0kW | 50.0kVA | 44.8kW | 56.0kVA | F6L912 | ECO32-1L/4 |
5 | BMA67OP | BMA67SP | 48.0kW | 60.0kVA | 53.2kW | 66.5kVA | F6L912T | ECO32-2L/4 |
6 | BMA78OP | BMA78SP | 56.0kW | 70.0kVA | 62.2kW | 77.7kVA | BF6L913 | ECO32-3L/4 |
7 | BMA95OP | BMA95SP | 68.0kW | 85.0kVA | 75.8kW | 94.7kVA | BF6L913 | ECP34-1S/4 |
8 | BMA110OP | BMA110SP | 80.0kW | 100.0kVA | 88.0kW | 110.0kVA | BF6L913 | ECP34-2S/4 |
9 | BMA116OP | BMA116SP | 84.0kW | 105.0kVA | 92.8kW | 116.0kVA | BF6L913C | ECP34-2S/4 |
10 | BMA142OP | BMA142SP | 104.0kW | 130.0kVA | 113.6kW | 142.0kVA | BF6L913C | ECP34-1L/4 |
Item No | Genset Model | Genset Model | Power Out Put | Beinei | Mecc Alte | |||
Prime 40 ℃ | Standby 27℃ | |||||||
1 | BMA40OP | BMA40SP | 29.8kW | 37.2kVA | 32.0kW | 40.0kVA | F4L912 | ECO32-1S/4 |
2 | BMA47OP | BMA47SP | 33.6kW | 42.0kVA | 37.6kW | 47.0kVA | F4L912T | ECO32-2S/4 |
3 | BMA54OP | BMA54SP | 38.4kW | 48.0kVA | 43.2kW | 54.0kVA | F4L912T | ECO32-3S/4 |
4 | BMA68OP | BMA68SP | 48.0kW | 60.0kVA | 54.4kW | 68.0kVA | F6L912 | ECO32-1L/4 |
5 | BMA80OP | BMA80SP | 57.5kW | 72.0kVA | 64.0kW | 80.0kVA | F6L912T | ECO32-2L/4 |
6 | BMA90OP | BMA90SP | 65.4kW | 81.7kVA | 72.0kW | 90.0kVA | F6L912T | ECO32-3L/4 |
7 | BMA114OP | BMA114SP | 81.6kW | 102.0kVA | 91.2kW | 114.0kVA | BF6L913 | ECP34-1S/4 |
8 | BMA130OP | BMA130SP | 96.0kW | 120.0kVA | 104.0kW | 130.0kVA | BF6L913 | ECP34-2S/4 |
9 | BMA140OP | BMA140SP | 101.0kW | 126.0kVA | 112.0kW | 140.0kVA | BF6L913C | ECP34-2S/4 |
10 | BMA170OP | BMA170SP | 125.0kW | 156.0kVA | 136.0kW | 170.0kVA | BF6L913C | ECP34-1L/4 |
Item No | Genset Model | Genset Model | Power Out Put | Beinei | Mecc Alte | |||
Prime 40 ℃ | Standby 27℃ | |||||||
1 | BMA40OP | BMA40SP | 30.0kW | 37.2kVA | 32.0kW | 40.0kVA | F4L912 | ECO32-1S/4 |
2 | BMA47OP | BMA47SP | 33.6kW | 42.0kVA | 37.6kW | 47.0kVA | F4L912T | ECO32-2S/4 |
3 | BMA54OP | BMA54SP | 38.4kW | 48.0kVA | 43.2kW | 54.0kVA | F4L912T | ECO32-3S/4 |
4 | BMA68OP | BMA68SP | 48.0kW | 60.0kVA | 54.4kW | 68.0kVA | F6L912 | ECO32-1L/4 |
5 | BMA76OP | BMA76SP | 54.4kW | 68.0kVA | 60.5kW | 75.6kVA | F6L912T | ECO32-2L/4 |
6 | BMA90OP | BMA90SP | 64.0kW | 80.0kVA | 71.6kW | 89.5kVA | F6L912T | ECO32-3L/4 |
7 | BMA114OP | BMA114SP | 81.6kW | 102.0kVA | 91.2kW | 114.0kVA | BF6L913 | ECP34-1S/4 |
8 | BMA130OP | BMA130SP | 96.0kW | 120.0kVA | 104.0kW | 130.0kVA | BF6L913 | ECP34-2S/4 |
9 | BMA140OP | BMA140SP | 101.0kW | 126.0kVA | 112.0kW | 140.0kVA | BF6L913C | ECP34-2S/4 |
10 | BMA158OP | BMA158SP | 116.0kW | 145.0kVA | 126.4kW | 158.0kVA | BF6L913C | ECP34-1L/4 |
11 | BMA170OP | BMA170SP | 125.0kW | 156.0kVA | 136.0kW | 170.0kVA | BF6L913C | ECP34-2L/4 |
Standard Scope of Supply: | ||||||||
Open Type Genset: 1. BEINEI Air Cooled G-Drive Engine; 2. Mecc Alte Brushless AC Alternator; 3. Mild Steel Skid Base with set mount anti-vibration isolators and 6-8 hours Base Fuel Tank; 4. Set Mount Bernini Be24 Control Panel with ComAp AMF25 and Deepsea 5110 as option; 5. Standard 3P Fixed Type MCCB; 6. Flexible Bellow and Industrial Type Silencer; 7. Lead Acid Battery; 8. O&M Manual; | ||||||||
Sound Proof Genset: 1. BEINEI Air Cooled G-Drive Engine; 2. Mecc Alte Brushless AC Alternator; 3. Mild Steel Skid Base with set mount anti-vibration isolators and 6-8 hours Base Fuel Tank; 4. Sound Proof Canopy Enclosure,Noise Level ≤75dBA@7M; 5. Set Mount Bernini Be24 Control Panel with ComAp AMF25 and Deepsea 5110 as option; 6. Standard 3P Fixed Type MCCB; 7. Flexible Bellow and Residential Type Silencer; 8. Lead Acid Battery; 9. O&M Manual; | ||||||||
RatingDefinitions | ||||||||
Prime Power | ||||||||
These ratings are applicable for supplying continuous electrical power ( at variable load ) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply above specified overload standby power for 1 hour in 12 hour. | ||||||||
Standby Power | ||||||||
These ratings are applicable for supplying continuous electrical power ( at variable load ) in event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated and don't allowed continuous. | ||||||||
Note: | ||||||||
Standard reference conditions 27℃ Air Inlet Temp, 152.4m (500ft) A.S.L.60% relative humidity. All engine performance data based on the above mentioned maximum continuous ratings. Fuel consumption data at full load with diesel fuel with specific gravity. |